Customer Support
0
Close

Categories

Filters

    HOBO CTD Sensor for MX800 series

    €1.454,47
    • Including 21% Tax: €1.454,47
    • Excluding VAT: €1.202,04
    0 In stock: 3-6 Weeks
    A Conductivity/Temperature/Depth sensor for use with HOBO MX800 Series Water Loggers with sensor options available for 13, 30, 100 or 250 feet in a wide range of underwater environments; for use in freshwater or saltwater.... Show more
    • Free shipping in the Netherlands from € 35,- *
    • Ordered before 5 p.m. on working days? Shipped the same day!
    • 14-day money back guarantee
    • We are happy to think along!

    Product description

    The CTD sensor is an interchangeable sensor that works with HOBO MX800 Series Water Loggers to measure conductivity, temperature, and water level. With this sensor attached to a HOBO MX800 Series Water Logger, the logger can also calculate specific conductance, salinity, and total dissolved solids (TDS).

    The CTD sensor can be attached directly to the fully submersible MX801 model, or attached via cable to the direct read MX802 model, which doesn’t require having to pull the sensor out of the water to download data.

    Features
    • 4-electrode conductivity sensor provides wide measurement range for monitoring freshwater or saltwater
    • Conductivity sensor is centrally located to minimize effects from stilling wells or protective guards
    • Durable ceramic water level sensor, located in the sensor tip for accurate measurement of shallow water levels
    • Get water level directly with the MX802, no need for post-processing
    • 1” diameter for use in narrow wells (with cable to MX802 above the well)
    • Temperature sensor placement near the sensor tip for fast response time
    • Specially treated stainless steel holds up in saltwater

    Please note:

    Requires a HOBO MX801 or MX802 Data Logger, the HOBOconnect app, and a compatible mobile device or Windows computer. System requirements for the app can be found at the bottom of the HOBOconnect software page.

    Specifications HOBO CTD Sensor for MX800 series
     
    Conductivity Measurements
     
    Measurement Range
    • Electrical conductivity and specific conductance: 0 to 100,000 µS/cm
    • Salinity using PSS-78: 2 to 42 PSU
    • Total Dissolved Solids (TDS): 0 to 100,000 mg/L

    Calibrated Range

    • Electrical conductivity: 50 to 80,000 µS/cm
    • 5° to 35°C
    • 41° to 95°F

    Accuracy

    • Conductivity: +/-2% or 15 µS/cm whichever is greater
    • Salinity: +/-2% of reading or 0.1 PSU, whichever is greater

    Resolution

    • Conductivity: 0.1 µS/cm from 0 to 1,000 µS/cm
    • 1 µS/cm from 1,000 to 10,000 µS/cm
    • 10 µS/cm from 10,000 to 100,000 µS/cm
    • TDS: 0.1 mg/L
    • Salinity: 0.01 PSU

    Response Time

    • 1 second to 90% at a stable temperature

    Absolute Pressure and Water Level Measurements W-CTD-01

    • Range: 0 to 207 kPa (0 to 30 psia); approximately 0 to 9 m (0 to 30 ft) of water depth at sea level, or 0 to 12 m (0 to 40 ft) of water at 3,000 m (10,000 ft) of altitude
    • Factory Calibrated Range: 69 to 207 kPa (10 to 30 psia), 0° to 40°C (32° to 104°F)
    • Burst Pressure: 310 kPa (45 psia) or 18 m (60 ft) depth
    • Water Level Accuracy*: Typical error: ±0.05% FS, 0.5 cm (0.015 ft) water. Maximum error: ±0.1% FS, 1.0 cm (0.03 ft) water
    • Raw Pressure Accuracy**: ±0.3% FS, 0.62 kPa (0.09 psi) maximum error
    • Resolution: <0.02 kPa (0.003 psi), 0.21 cm (0.007 ft) water
    • Pressure Response Time***: <1 second to 90% at a stable temperature

    Absolute Pressure and Water Level Measurements W-CTD-02

    • Range: 0 to 400 kPa (0 to 58 psia); approximately 0 to 30.6 m (0 to 100 ft) of water depth at sea level, or 0 to 33.6 m (0 to 111 ft) of water at 3,000 m (10,000 ft) of altitude
    • Factory Calibrated Range: 69 to 400 kPa (10 to 58 psia), 0° to 40°C (32° to 104°F)
    • Burst Pressure: 500 kPa (72.5 psia) or 40.8 m (134 ft) depth
    • Water Level Accuracy*: Typical error: ±0.05% FS, 1.5 cm (0.05 ft) water. Maximum error: ±0.1% FS, 3.0 cm (0.1 ft) water
    • Raw Pressure Accuracy**: ±0.3% FS, 1.20 kPa (0.17 psi) maximum error
    • Resolution: <0.04 kPa (0.006 psi), 0.41 cm (0.013 ft) water
    • Pressure Response Time***: <1 second to 90% at a stable temperature

    Absolute Pressure and Water Level Measurements W-CTD-03

    • Range: 0 to 850 kPa (0 to 123.3 psia); approximately 0 to 76.5 m (0 to 251 ft) of water depth at sea level, or 0 to 79.5 m (0 to 262 ft) of water at 3,000 m (10,000 ft) of altitude
    • Factory Calibrated Range: 69 to 850 kPa (10 to 123.3 psia), 0° to 40°C (32° to 104°F)
    • Burst Pressure: 1,200 kPa (174 psia) or 112 m (368 ft) depth
    • Water Level Accuracy*: Typical error: ±0.05% FS, 3.8 cm (0.125 ft) water. Maximum error: ±0.1% FS, 7.6 cm (0.25 ft) water
    • Raw Pressure Accuracy**: ±0.3% FS, 2.55 kPa (0.37 psi) maximum error
    • Resolution: <0.085 kPa (0.012 psi), 0.87 cm (0.028 ft) water
    • Pressure Response Time***: <1 second to 90% at a stable temperature

    Absolute Pressure and Water Level Measurements W-CTD-04

    • Range: 0 to 145 kPa (0 to 21 psia); approximately 0 to 4 m (0 to 13 ft) of water depth at sea level, or 0 to 7 m (0 to 23 ft) of water at 3,000 m (10,000 ft) of altitude
    • Factory Calibrated Range: 69 to 145 kPa (10 to 21 psia), 0° to 40°C (32° to 104°F)
    • Burst Pressure: 310 kPa (45 psia) or 18 m (60 ft) depth
    • Water Level Accuracy*: Typical error: ±0.075% FS, 0.3 cm (0.01 ft) water. Maximum error: : ±0.15% FS, 0.6 cm (0.02 ft) water
    • Raw Pressure Accuracy**: ±0.3% FS, 0.43 kPa (0.063 psi) maximum error
    • Resolution: <0.014 kPa (0.002 psi), 0.14 cm (0.005 ft) water
    • Pressure Response Time***: <1 second to 90% at a stable temperature
    Temperature Measurements (All Models)
    • Range: -20° to 50°C (-40° to 122°F), non-freezing water
    • Accuracy: ±0.15°C (±0.27°F) from 0° to 50°C (32° to 122°F)
    • Resolution: 0.01°C at 25°C (0.018°F at 77°F)
    • Response Time: 3 minutes to 90% in water (typical)
    • Drift: <0.1°C (0.18°F) per year
    Sensor
    • Dimensions
      • 2.5 cm (1 inch) diameter, 15 cm (6 inches) length
      • Weight
      • Approximately xx g (xx oz) in air; approximately xx g (xx oz) in saltwater
      • Wetted Materials
      • Passivated 316 Stainless steel housing rated for use in saltwater, Viton and Buna-N O-rings, PET sensor connector
        Depth sensor: ceramic
        Conductivity sensor: PET, platinum plating on electrodes
        Note: Sensor should be mounted so that it is not in contact with other metals
      • Environmental Rating
      • IP68; Waterproof to pressure sensor burst pressure ratin

    Specifications

    Article number
    W-CTD-01

    Reviews

    0 from 5Based on 0 reviews
    Create your own review

    There are no reviews written yet about this product..

    Related products

    Complete your order

    HOBO CTD Sensor for MX800 series
    € 1.454,47
    HOBO CTD Sensor for MX800 series
    CTD Sensor, 9m (30') Depth
    0 In stock: 3-6 Weeks