Customer Support
0
Close

Categories

Filters

    HI4012 Lead/Sulfate Half-Cell Ion Selective Electrode, Solid State

    €1.126,26
    • Including 21% Tax: €1.126,26
    • Excluding VAT: €930,79
    0 In stock: Delivery time on request
    The HI4012 lead/sulfate selective electrode is a potentiometric half-cell sensor... Show more
    • Free shipping in the Netherlands from € 35,- *
    • Ordered before 5 p.m. on working days? Shipped the same day!
    • 14-day money back guarantee
    • We are happy to think along!

    Product description

    The HI4012 lead/sulfate selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed lead sulfide sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.

    Hanna’s solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.

    For the HI4012 to measure lead accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the lead ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free lead ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4012 lead/sulfate solid state ISE can measure from 1µM (0.21 mg/L) to 0.1M (20,700 mg/L).

    The HI4012 can also be used as an indicator to follow the progress and detect the endpoint of a precipitation titration of sulfate. During the titration, the lead/sulfate ISE follows the lead concentration while a lead perchlorate solution is used to titrate the sample. The lead in the titrant solution reacts with the sulfate ions present in the sample to form a precipitate. Once all of the lead and sulfate ions have reacted, a change in mV occurs to signal the endpoint, and ultimately the sulfate concentration

     

    Conversion Table for Pb2+

     Multiply

    moles/L (M) to ppm (mg/L)

    2.072 x 105

    ppm (mg/L) to M (moles/L)

    4.826 x 10-6

    Specifications

    Article number
    HI4012

    Reviews

    0 from 5Based on 0 reviews
    Create your own review

    There are no reviews written yet about this product..

    Related products

    Complete your order

    HI4012 Lead/Sulfate Half-Cell Ion Selective Electrode, Solid State
    € 1.126,26
    HI4012 Lead/Sulfate Half-Cell Ion Selective Electrode, Solid State
    0 In stock: Delivery time on request
    Add to cart

    Recently viewed