HI4012 Ionenselektive Elektrode für Blei/Sulfat, Solid State

€1.126,26
  • Inklusive 21% MwSt.: €1.126,26
  • Ohne MwSt: €930,79
0 Auf Lager: Lieferzeit auf Anfrage
The HI4012 lead/sulfate selective electrode is a potentiometric half-cell sensor... Mehr anzeigen
  • Versandkosten nur 7,50 € nach Deutschland
  • An Werktagen vor 17 Uhr bestellt? Versand am selben Tag!
  • 14 Tage Rückgaberecht
  • Bei uns ist nichts unmöglich!

Produktbeschreibung

The HI4012 lead/sulfate selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed lead sulfide sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.

Hanna’s solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.

For the HI4012 to measure lead accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the lead ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free lead ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4012 lead/sulfate solid state ISE can measure from 1µM (0.21 mg/L) to 0.1M (20,700 mg/L).

The HI4012 can also be used as an indicator to follow the progress and detect the endpoint of a precipitation titration of sulfate. During the titration, the lead/sulfate ISE follows the lead concentration while a lead perchlorate solution is used to titrate the sample. The lead in the titrant solution reacts with the sulfate ions present in the sample to form a precipitate. Once all of the lead and sulfate ions have reacted, a change in mV occurs to signal the endpoint, and ultimately the sulfate concentration

 

Conversion Table for Pb2+

 Multiply

moles/L (M) to ppm (mg/L)

2.072 x 105

ppm (mg/L) to M (moles/L)

4.826 x 10-6

Eigenschaften

Artikelnummer:
HI4012

Bewertungen

0 from 5Based on 0 reviews
Eigene Bewertung erstellen

Es wurden noch keine Bewertungen für dieses Produkt abgegeben..

Verwandte Produkte

Vervollständigen Sie Ihre Bestellung

HI4012 Ionenselektive Elektrode für Blei/Sulfat, Solid State
€ 1.126,26
HI4012 Ionenselektive Elektrode für Blei/Sulfat, Solid State
0 Auf Lager: Lieferzeit auf Anfrage
Zum Warenkorb hinzufügen

Zuletzt angesehen